<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.59 PDR60 : "Error occurred on <physical disk> : <error code>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
<error code> = " Error 123"
2.3.8.60 PDR61 : "The rebuild of <physical disk> failed due to errors on the source physical
disk."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.61 PDR62 : "The rebuild failed due to errors on the target <physical disk>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.62 PDR63 : "A bad disk block on <physical disk> cannot be reassigned during a write
operation."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.63 PDR64 : "An unrecoverable disk media error occurred on <physical disk>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.64 PDR65 : "<physical disk> is marked as missing."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.65 PDR66 : "<physical disk> that was marked as missing has been replaced."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.66 PDR67 : "An unsupported physical disk drive has been detected."
2.3.8.67 PDR68 : "Dedicated spare <PD Name> imported as global due to missing disk
groups."
When event is generated, message will have the following substitutions:
<PD Name> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
2.3.8.68 PDR69 : "Rebuild not possible on <physical disk>."
When event is generated, message will have the following substitutions: