Virtual Console FCD-USBxx Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Oprogramowanie Virtual Console FCD-USBxx. Virtual Console FCD-USBxx Technical data Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 106
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
HP Integrity Virtual Machines 4.2.5: Release
Notes
HP Part Number: 5900-1482
Published: January 2011, Edition 13.3
Przeglądanie stron 0
1 2 3 4 5 6 ... 105 106

Podsumowanie treści

Strona 1 - HP Part Number: 5900-1482

HP Integrity Virtual Machines 4.2.5: ReleaseNotesHP Part Number: 5900-1482Published: January 2011, Edition 13.3

Strona 2

List of Tables1-1 Guest and VM Host Support...16

Strona 3 - Table of Contents

11.8 Storage Interface SupportNotesIntegrity VMVersionV.04.20.05 (bothVIO and AVIOunless explicitlyexcluded)Integrity VMVersion B.04.20(both VIO and A

Strona 4 - 4 Table of Contents

11.8.2 Multipathing Software SupportMultipathing software is supported on the Integrity VM Host system. Unless specified otherwise,multipathing is sup

Strona 5 - Table of Contents 5

• On EVA 4000/6000/8000, all released firmware revisions support Active-Active configuration.Therefore, no action is necessary on these arrays.• EVA 3

Strona 6 - 6 Table of Contents

A hpvmhostgdev Manpage103

Strona 7 - Table of Contents 7

hpvmhostgdev(1M)NAMEhpvmhostgdev -- Manages Integrity VM Host devices available for virtual machine access.SYNOPSIShpvmhostgdev [-H | [-u] | { -a | -

Strona 8 - 8 Table of Contents

-rRecovers the Integrity VM device management database.-u Uses disklist device cache (Do not force hardware scan.).NOTE: This option is used to speed

Strona 9 - Table of Contents 9

hpvmcollect(1M), hpvmmgmt(1M), hpvmpubapi(3)106 hpvmhostgdev Manpage

Strona 10 - List of Tables

About This DocumentThe HP Integrity Virtual Machines Release Notes document describes the latest enhancements andchanges to the HP Integrity Virtual M

Strona 11 - About This Document

Document OrganizationThis document contains information that supplements the information in the Integrity VirtualMachines Version 4.2: Installation, C

Strona 12 - Publishing History

Publication DateEditionNumberSupported Integrity VMVersionSupported VM Host OperatingSystemPublication NumberApril 20062.3HP Integrity VirtualMachines

Strona 13

HP Insight Remote SupportHP strongly recommends that you install HP Insight Remote Support software to complete theinstallation or upgrade of your pro

Strona 14 - HP Encourages Your Comments

1 IntroductionThank you for installing HP Integrity Virtual Machines (also called Integrity VM). This ReleaseNotes document describes the changes in t

Strona 15 - 1 Introduction

1.1 New Features and Enhancements in This Version of Integrity VMThis section describes how the current version of Integrity VM has been enhanced over

Strona 16 - 1.2 Guest and VM Host Support

Table 1-1 Guest and VM Host Support (continued)VM Host on HPIntegrity rx2800 i2VM Host on HPIntegrity ServersVM Host on HPIntegrity Superdome21VM Host

Strona 17 - 1.3 Guest Management Software

the guest management software on each guest can cause problems that are difficult to diagnoseand solve.18 Introduction

Strona 18 - 18 Introduction

2 Installation NotesThis chapter contains notes about installing and upgrading Integrity VM and associated softwareon the VM Host system.2.1 Installin

Strona 19 - 2 Installation Notes

© Copyright 2011 Hewlett-Packard Company, L.P.Legal NoticesConfidential computer software. Valid license from HP required for possession, use or copyi

Strona 20 - # /sbin/init.d/ovpa start

2.3.1 After Installation, Integrity VM Might Hang Upon RebootDue to a timing issue, Integrity VM V4.2.5 might hang upon reboot after it is installed.

Strona 21 - Backing Device

• You might receive a read error while reading filesets from the OE media, with a “Bad Address(14)” wording in the error message.Workaround: Install t

Strona 22 - 22 Installation Notes

NOTE: Patch PHKL_37815 contains the new USB driver delivered with HP–UX 11i v3 (0903).Consequently, if you install this patch on an HP–UX 11i v3 syste

Strona 23 - VM V4.2.5

2.3.10 Failures in Key ApplicationsSome applications fail when run on HP-UX with large pages configured (larger than 8K). Thosethat are frequently use

Strona 24 - Software

Dynamics Virtual Software Environment software versions earlier than V4.0 must upgrade toHP Insight Dynamics — VSE V4.1 (which contains VMMgr V4.0).VM

Strona 25 - # swremove gWLM-Agent

utilities and Serviceguard, as documented in the HP Integrity Virtual Machines Installation,Configuration, and Administration manual.• Using backup so

Strona 26 - 2.3.17 Trunking Software

If you have installed the HP Integrity Virtual Machines Manager software, you must upgradeit to a version that supports this version of Integrity VM.T

Strona 27

installed, installing the patch by itself does not prevent the problem. Reconfiguration of dynamicmemory settings is necessary for the guest to be abl

Strona 28

Table 2-1 VM Host Patches (continued)CommentDescription/ImpactFixAffected Integrity VMVersionAffected HP-UX (VMHost) VersionMust installPHKL_33605 bef

Strona 29

Table 2-1 VM Host Patches (continued)CommentDescription/ImpactFixAffected Integrity VMVersionAffected HP-UX (VMHost) VersionMandatory patch:HPVM A.03.

Strona 30

Table of ContentsAbout This Document...11Intended

Strona 31

Table 2-1 VM Host Patches (continued)CommentDescription/ImpactFixAffected Integrity VMVersionAffected HP-UX (VMHost) VersionHPVM B.04.10 COREPATCHBug

Strona 32 - Table 2-3 HP-UX Guest Patches

Table 2-1 VM Host Patches (continued)CommentDescription/ImpactFixAffected Integrity VMVersionAffected HP-UX (VMHost) VersionHostAVIOStor:Support for S

Strona 33

Table 2-2 Do Not Install Product or PatchCommentDescription/ImpactFixAffected Integrity VMVersionAffected HP-UX HostVersionAn Integrity VMguest that u

Strona 34

Cumulative ARPAtransport patch,resolves panic.Requires prerequisitePHNE_32277.Bug fixPHNE_35182A.01.00 or later11i v2 0505 or laterIntegrity VM V2.0 o

Strona 35

Table 2-3 HP-UX Guest Patches (continued)Fixes EFI bootpathwith AVIO.Bug fixPHKL_37091(11.23.0712)A.03.5011i v2 0505 through0706Bug fixPHSS_37843A.03.

Strona 36

Table 2-3 HP-UX Guest Patches (continued)11i v2 guestvmGuestLibVirtProviderenhancementsEnhancementsPHSS_41415A.04.20.0511i v2 071211i v2 vmToolsVirtpr

Strona 37 - 3 Creating Virtual Machines

Table 2-6 Windows PatchesCommentDescription/ImpactFixAffected Integrity VMVersionAffected Guest OS andVersionMicrosoft patchescorrect a compilerissue

Strona 38 - 38 Creating Virtual Machines

3 Creating Virtual MachinesThis chapter contains notes about creating and configuring virtual machines on the VM Hostsystem.3.1 Changes and Issues in

Strona 39 - 4 Installing Guests

3.2.4 Do Not Run hpvmstart in Background When Starting Multiple Guests WithResource ConflictsDo not run the hpvmstart command in the background when s

Strona 40 - 40 Installing Guests

4 Installing GuestsThis chapter describes notes pertaining to installing guest software on the virtual machines.4.1 Windows GuestsThe following sectio

Strona 41 - # hpvmstop -P winguest

2.9 Patches Required for SUSE Enterprise Linux Guests...363 Creating Virtual Machin

Strona 42 - 4.2 HP-UX Guests

4.1.2.6 Palhaltlight in Windows Server 2008 GuestsThe use of palhaltlight is enabled by default in a Windows 2008 guest, which allows the VMHost to be

Strona 43

• After the automatic reboot, Windows controls the console. When you see the SAC> prompt,use Esc-Tab to change the channel to the product key promp

Strona 44 - 44 Installing Guests

copy the file /opt/hpvm/guest-images/common/nvram to/var/opt/hpvm/guests/vm_name/nvram on the VM Host system. This procedure restoresthe copy of the N

Strona 45

[my_guest] vMP> inInsertable Guest DevicesNum Hw-path (Bus,Slot,Tgt) Gdev--------------------------------------------[1] 0/0/1/0.1

Strona 46 - 4.3 Linux Guests

-------------------------------------------------------------------------[1] 0/0/0/0.1.0 (0,0,1) dvd file /tmp/iso/1131_0909_DV

Strona 47 - Rescue:~ #

• HP-UX 11i v2: PHCO_40685 and PHKL_40684• HP-UX 11i v3: PHKL_39482 and PHCO_38777You can download these patches from the ITRC website, http://itrc.hp

Strona 48 - Rescue:/# reboot

4.2.2.7 Do Not Use the iomap(7) Mechanism on HP-UX GuestsThe iomap(7) mechanism allows you to map physical I/O addresses into the user processaddress

Strona 49 - 4.3 Linux Guests 49

The guest parameter settings for Linux guests are listed in the HP Integrity Virtual Machines 4.2:Installation, Configuration, and Administration manu

Strona 50

NOTE: The cloned guest's boot disk SCSI WWID can be copied from the /dev/disk/by-id/ device names. For example, the cloned guest boot disk device

Strona 51

The SUSE Linux RPM guest kit is actually two parts, a guest kit and a provider kit. TheHpvm.*.rpm kit contains:• Tuning scripts• hpvminfo• hpvmcollect

Strona 52 - 4.4 OpenVMS Guests

4.3.1 Changes and Issues in This Release...464.3.2 Known Issues a

Strona 53 - 4.4.6 Formatting SYSTEM UUID

processor file system, which might lead to confusion as to the actual number of CPUs configuredin the guest.4.3.2.8 HP SIM CMS Cannot Connect to SLES1

Strona 54 - 54 Installing Guests

mptbase: ioc0: ERROR - Doorbell ACK timeout (count=4999), IntStatus=80000000! mptbase: ioc0: ERROR - Doorbell ACK timeout (count=4999), IntStatus=800

Strona 55 - 5 Using Integrity VM Commands

4.3.2.17 Serviceguard in VM Host ConfigurationThe default KILLTIME of 10 seconds (in hpvmsg_stop for a legacy package) and a wait of 10seconds (in hpv

Strona 56 - When Guest Booted to EFI

Use one of the following solutions to fix either of these issues:• Set the VM Host base_pagesize = 64K (See the base_pagesize(5) manpage for details o

Strona 57

$ part2 = f$fao("!AS",f$ext(20,4,uuid))$ part3 = f$fao("!AS",f$ext(16,4,uuid))$ part4 = f$fao("!AS!AS",f$ext(14

Strona 58

5 Using Integrity VM CommandsThis chapter contains notes about the Integrity VM commands.5.1 Changes and Issues in This ReleaseThe following sections

Strona 59

the kernel version, Linux guests might support enabling or disabling virtual CPUs by writinginto /sys/devices/system/cpu/cpuN/ online, as on a physica

Strona 60

devices if they have legitimate WWIDs in the /var/opt/hpvm/common/hpvm_mgmtb_pre1131device database file.5.2.6.2 Error Comments from hpvmdevtranslate

Strona 61 - 6 Guest Administration

virtual device to sharable using the hpvmdevmgmt command. Incorrectly marking a virtualdevice as sharable can lead to device conflicts and data corrup

Strona 62 - Server Management

hpvmmodify: WARNING (test_duperr): File size of: 0 (bytes) for disk backing file: /tmp/zero.size.2 must be equal to or greater than: 512 (bytes), or t

Strona 63 - 6.2.3 Guest User Accounts

5.2.13 Do Not Attempt to Remove Busy Virtual Devices...585.2.14 Missing uuid or .vmid Fil

Strona 65 - # hpvmstart –P guestname

6 Guest AdministrationThis chapter contains information about managing Integrity VM guests.6.1 Changes and Issues in this ReleaseThe following section

Strona 66 - 66 Guest Administration

NOTE: If you add new devices in the future, run the hpvmhostgdev -a script again. Ifyou want to select the guest devices instead of adding all of them

Strona 67 - A VM encountered with no size

6.2.1 Creating Virtual Machine Administrator and Operator AccountsIn versions of Integrity VM prior to A.03.00, Admin console access is available, and

Strona 68

testme1# useradd -r no -g users -s /opt/hpvm/bin/hpvmconsole \ -c "Console access to guest 'testme'" \> -d /var/opt/hpvm/guest

Strona 69 - 7 Networking Information

devices in the guest configuration and evaluate the Host storage configuration with respect tothese devices and the adapters used to access them.6.2.8

Strona 70

used by guests but requires users to verify or provide activation modes and package dependenciesfor the backing stores.The hpvmsg_package script creat

Strona 71

6.2.13.10 Reenter Command to Start PackagesThe procedure for configuring and starting guest packages includes the cmrunpkg command.This command does n

Strona 73 - 7.2.10 Supported Adapters

7 Networking InformationThis chapter contains notes about configuring networks for virtual machines.7.1 Changes and Issues in This ReleaseThe followin

Strona 74 - HPVMMACADDRFRAMES=n

7.2.2 AVIO LAN Devices Left Unclaimed by OpenVMS Guest if vswitch is Down at Boot...707.2.3 Known Limitation on OpenVMS Guests and HP-UX Guests

Strona 75

lan0 UP 0x0017A4AB5461 igelan 1000Base-Tlan1 UP 0x0017A4AB5460 igelan 1000Base-Tlan2 UP 0x001A4

Strona 76 - 7.2.22 Restarting Vswitches

booted prior to booting the vswitch, or if the corresponding network interface on the VM Hostis not cabled during the guest boot time.If you encounter

Strona 77 - lanadmin -X drv_pr_on ppa

alias eth0 lgssn2. Issue the depmod -a command to inform the kernel of the device type change. After youissue the command, you should see the followin

Strona 78 - 7.2.26 Other Issues and Notes

be allowed to deliver time (allow guests to be a time consumers). Because a VM guest neverdelivers time, you do not need to configure the local clock

Strona 79 - 8 Storage Information

• NC360m — C-class Mezz card• NC364m — C-class Mezz card7.2.11 Calculating the Actual Utilization of the Virtual Network CardThe emulation of the virt

Strona 80 - 80 Storage Information

You can set the HPVMMACADDRFRAMES tunable to zero (0), which completely eliminates the MACaddress verification. However, HP recommends that you do so

Strona 81 - HP-UX 11i v2 Guest

In this example, the VLANs are configured over the vswitch vmlan4. This vswitch is created onPPA 4 on the VM Host.The following table shows the nwmgr

Strona 82

• You change the network interface characteristics on the VM Host; for example, by using thenwmgr command to change checksum offloading (CKO).• You no

Strona 83

NOTE: These change are not carried over to subsequent reboots of the system. To maintain theconfiguration over reboots of the guest, the administrator

Strona 84 - 8.2.20 AVIO Limitations

8 Storage InformationThis chapter contains information about storage devices used as backing stores for guest virtualdevices.8.1 Changes and Issues in

Strona 85

8.2.20.2 iSCSI-Based Backing Stores with AVIO Require Host AVIOstor B.11.31.1009.01...848.2.20.3 Modifying the Storage Adapter from scsi to avio

Strona 86

If the LV or file backing store file name is 55 characters long and the guest is a HP-UX11i v3 guest, guest panic or disk dsf name change is seen on s

Strona 87 - Management

8.2.6 Agile Device Name RecommendationsThe Integrity VM commands supports mass storage agile device names. Use of agile devicenames (with the exceptio

Strona 88

/dev/dsk/c0t0d0s3 /dev/rdsk/c0t0d0s3disk 16 0/0/5/0.0.0 sdisk CLAIMED DEVICE HP Virtual Disk

Strona 89 - 9 Migrating Virtual Machines

8.2.14 The hpvmmodify Command Fails to Change a DVDThe hpvmmodify command might fail to change a Virtual FileDVD if the device has alreadybeen modifie

Strona 90 - 9.2.4 NR Guest State

8.2.20 AVIO LimitationsThe following sections describe the current limitations using AVIO.8.2.20.1 iSCSI-Based Backing Stores Not Supported with Physi

Strona 91

# hpvmstatus -P aviotest[Storage Interface Details]Guest PhysicalDevice Adaptor Bus Dev Ftn Tgt Lun Storage Devi

Strona 92

In this example, exp1 / exp2 represents the quotient from exp1 divided by exp2 (integerdivision), and exp1 % exp2 finds modulo of exp1 divided by exp2

Strona 93 - 10 Error Logging

1. In the guest, rmsf the target path (tgtpath Class in ioscan display) corresponding to the lunpath.2. In the guest, perform an ioscan.8.2.22 Storage

Strona 95 - 11.2 Integrity VM Upgrades

9 Migrating Virtual MachinesThis chapter contains information about migrating virtual machines.9.1 Changes and Issues in This ReleaseThe following sec

Strona 96

11.8.3 EVA Series Firmware Requirement...10111.9 Network Interface S

Strona 97 - 11.4 HP-UX Guest Support

Opening minor device and creating guest machine container Creation of VM, minor device 1hpvmmigrate: ERROR (vmname): Remote message: Target g

Strona 98 - 11.6 OpenVMS Guest Support

9.2.7 Unpresenting SAN Devices to Integrity VM HostsUnpresenting SAN devices that were configured to be used by guests causes the guest to fail tostar

Strona 100

10 Error LoggingThis chapter contains information about the way Integrity VM logs messages.10.1 Changes and Issues in This ReleaseThere are no new err

Strona 101

10.2.6 Virtual Console Event Logs Different from Physical Machine LogsThe virtual console allows you to use the sl command to list the System Event lo

Strona 102 - 11.10 AVIO Support

11 Integrity VM Support PolicyThis chapter describes the HP Integrity Virtual Machine support policies and software versionrequirements for Integrity

Strona 103 - A hpvmhostgdev Manpage

# hpvmstatus -P guestname -d | grep -w scsi# hpvmstatus -P guestname -d | grep -w lan• Integrity VM V4.2.5 will be the last release to support Microso

Strona 104 - DESCRIPTION

11.4 HP-UX Guest SupportNotesIntegrity VMB.04.20.05Integrity VMB.04.20Integrity VMVersionB.04.10Integrity VMVersion B.04.00Integrity VMVersionA.03.50T

Strona 105 - EXAMPLES

NOTE: For information about required patches, see Chapter 2 (page 19).HP-UX patches might be required for proper operation. Install these patches on H

Strona 106 - 106 hpvmhostgdev Manpage

1Intel® Itanium® 2 9000 Series and Intel Itanium 2 9100 Series2 Requires V4.2 with the following VM Host patches:PHSS_40875 1.0 HPVM B.04.20 CORE PATC

Komentarze do niniejszej Instrukcji